Part Number Hot Search : 
WFF2N65B PL100 C3504 2002M CY7C199 KSE800 0CTQ1 APA3160A
Product Description
Full Text Search
 

To Download TFS70N Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 TFS70N.doc
Version 1.6
01.04.99
VI TELEFILTER
Filter specification
Package, pin connection and 50 matching network 23 C 0 dBm. for input: 56,8 - 40,8 pF. for output: 46,5 - 35,3 pF. ( see Application Note)
TFS 70 N
1/3
1. Measurement condition Ambient temperature TA: Input power level: Terminating impedances in fc:
(see page 2.)
[ 27,9 + j 28,4 ] [ 30,6 + j 22,0 ]
2. Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 70N is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequence fc is the arithmetic mean value of the upper and lower frequencies at the 20 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the production tolerance scheme.
Data Insertion loss (Reference level) Reference frequency Pass band (-2 dB) : Bandwidth at ambient temperature: 1,0 1,5 2,0 3,0 20 35 45 50 dB - band width dB - band width dB - band width dB - band width dB - band width dB - band width dB - band width dB - band width fc ... fc 4,8 MHz arel ... ... ... ... ... fc fc fc fc fc 4,8 5,0 5,6 6,0 35 MHz MHz MHz MHz MHz ae
typ. value 20,6 70 dB MHz
tolerance / limit max 24 70 0,1 dB MHz
fc at ambient temperature (fCAT) :
fC - 4,8 MHz ... fC + 4,8 MHz
9,92 9,94 9,98 10,12 10,60 10,77 10,843 10,900 0,7
MHz MHz MHz MHz MHz MHz MHz MHz dB
min. 9,6 min. 10,0 min. 10,8 min. 11,2 max 2
MHz MHz MHz MHz dB
Amplitude ripple (p-p): Relative attenuation fc fc 4,8 MHz fc 5,4 MHz fc 5,6 MHz fc 6,0 MHz Group delay inpass band: Group delay ripple (p-p):
40 55 55...65 3,74 140 5,5 70 50 -87
dB dB dB s ns
max 2 max 3 min 35 min 45 min 50 max 4,5 max 200
dB dB dB dB dB s ns
fc ... fc 4,8 MHz
Deviation from linear phase (p-p): fc ... fc 5,0 MHz Crosstalk attenuation compared to main signal Triple transit attenuation compared to main signal Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature Operating temperature range Storage temperature range
dB dB ppm/K -94 ppm/K
fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz) 0 C ... + 60 C - 20 C ... + 85 C
Generated:
Wadim P. Dunzow
Checked/Approved:
Dr. Bert Wall
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70N.doc
Version 1.6
01.04.99
VI TELEFILTER
Filter specification
TFS 70 N
2/3
3. Package 35 Max Pin 23 Pin 24 Pin 11 Pin 12 Pin 1-10, 13-22 Input Input RF Return Output Output RF Return Ground
20,5 Max
TFS 70 N tft L3
5,5 5,5 1 12
15,24 24 13
2,54
11x2,54 = 27,94
4. 50 matching network: 1 11 12
L2 L1
24 23 13
L3* C1*
L1 = 125 nH L2 = 60 nH C1 = 27 pF. *) L3 85 5 nH. L3 : L 3 C 1 = 2 f1 ,
f
1
= 94,3 0,3 MHz
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS70N.doc
Version 1.6
01.04.99
VI TELEFILTER
Filter specification
TFS 70 N
3/3
5. Air reflow temperature conditions
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS70N

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X